CKDYT - A-851-B SILICONE ADHESIVE
- MSDS: CKDYT
- Manufacturer: B F GOODRICH ADHESIVE SYSTEMS
- Product Name: A-851-B SILICONE ADHESIVE
- National Stock Number: 8040-01-023-4515
Product Identification
Product ID:A-851-B SILICONE ADHESIVE
MSDS Date:04/30/1989
FSC:8040
NIIN:01-023-4515
Status Code:A
MSDS Number: CKDYT
Responsible Party
AKRON, OH 44311
US
Emergency Phone: 1-216-374-5143
Info Phone: 216-374-2824
Cage: 4248X
Contractor
Telephone: 216-374-2824
Cage: 4248X
Ingredients
METHYL ETHYL KETONE
CAS: 78-93-3
RTECS: EL6475000
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
PHENOL*#
CAS: 108-95-2
RTECS: SJ3325000
OSHA PEL 5 PPM
ACGIH TLV: 5 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Health Hazards Acute and Chronic:INHALATION: NOSE AND THROAT IRRITATION
HEADACHE, NAUSEA, LOSS OF COORDINATION, DIZZINESS,
UNCONSCIOOUSNESS, AND EVEN ASPHYXIATION. SKIN CONTACT: MAY CAUSE
DE-FATTING OR DERMATITIS. EYE CONTACT: M AY CAUSE IRRITATION, OR
CORNEAL CLOADING. INGESTION: ASPIRATION INTO LUNGS MAY CAUSE
CHEMICAL PNEUMONITIS CHRONIC EFFECTS: MAY INCLUDE KIDNEY AND
LIVER DAMAGE AND DERMATITIS. REPORTS HAVE ASSO CIATED REPEATED
AND PROLONGED OCCUPATIONAL OVER-EXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN AND NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING AND INHALING THE CONTENTS MAY BE
HARMFUL OR FATAL.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR, IF NOT BREATHING, GIVE
ARTIFICIAL RESPIRATION, PREFERABLY MOUTH TO MOUTH, IF BREATHING
DIFFICULT GIVE OXYGEN, CALL A PHYSICIAN AT ONCE. SKIN CONTACT:
REMOVE CONTA MINATED CLOTHING AND LAUNDER BEFORE REUSE. WASH
AFFECTED AREA WITH PLENTY OF SOAP AND WATER. EYE CONTACT: FLUSH
WITH PLENTY OF WATER FOR AT LEAST 5 MIN. (HOLD EYE LIDS OPEN)
LONGER IF THERE IS IN DICATION OF RESIDUAL MATERIAL IN EYE.
INGESTION: CALL A PHYSICIAN IMMEDIATELY. INDUCE VOMITING ONLY AT
THE INSTRUCTIONS OF A PHYSICIAN. NEVER GIVE ANY THING BY MOUTH TO
AN UNCONSCIOUS PERSON.
Fire Fighting
Flash Point:=-6.5C, 20.F
20F
Lower Limits:2.0
Extinguishing Media:WATER FOG, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:DO NOT ENTER CONFINED FIRE SPACE WITHOUT
PROPER PROTECTIVE EQUIPMENT INCLUDING NIOSH APPROVED SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:VAPORS MAY BUILD UP IN POORLY VENTILATED
AREAS AND BE IGNITED, CAUSING FLASH FIRES OR EXPLOSIONS. VAPORS
ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG GROUND OR FLOOR TO SOURCE
OF IGNITION, CAUSING FLASH FIRES OR EXPLOSIONS.
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES, PROVIDE
ADEQUATE VENTILATION, AVOID BREATHING VAPORS, AVOID EYE AND SKIN
CONTACT. WIPE UP WITH RAGES, PAPER OR OTHER ABSORBENT. PLACE IN
SUITABLE CLOSED CONTAINERSS F OR DISPOSAL.
Handling
Handling and Storage Precautions:USE ONLY IN WELL VENTILATED
AREA.ELIMINATE SOURCES OF IGNITION SUCH AS SPARKS, FLAMES AND
NON-EXPLOSION PROOF DEVICES.AVOID PROLONGED/REPEATED SKIN
CONTACT/BREATHING OF VAPORS.FOR INDURRIAL USE ONLY.*
Other Precautions:IN ADDITION TO ANY LISTED PRECAUTIONS, YOU SHOULD
CONSULT YOUR OCCUPATIONAL SAFETY AND HEALTH SPECIALIST TO INSURE
THAT THE HANDLING PROCEDURES WILL BE ADEQUATE AND IN COMPLIANCE
WITH APPLICABLE LAWS AND REGULATIONS.
Exposure Controls
Respiratory Protection:FOR AIR CONTAMINANTS ABOVE TLV OR PERMISSIBLE
LIMITS USE NIOSH-APPROVED RESPIRATOR FOR ORGANIC VAPORS.
Ventilation:LOCAL EXHAUST TO KEEP VAPORS BELOW TLV OR PERMISSIBLE
LIMITS.
Protective Gloves:IMPERVIOUS.
Eye Protection:CHEMICAL GOGGLES.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:=79.4C, 175.F
B.P. Text:175F
Vapor Density:.AIR
Spec Gravity:0.865
Evaporation Rate & Reference:4.6 X N-BUTYL ACETATE
Appearance and Odor:LIGHT AMBER, STLY VISC LIQ W/ KETONE ODOR
Percent Volatiles by Volume:80%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:SEE INCOMPATIBLITY.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
SMOKE, ALIPHATICS AND OTHERS.
Disposal
Waste Disposal Methods:THIS MATERIAL, IF DISCARDED, IS HAZARDOUS AND
MUST BE PROPERLY STORED, TRANSPORTED, AND DISPOSED OF IN ACCORDANCE
WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS.
Toxicology
Toxicological Information:EMBRY/FETOTOXIC EFFECTS HAVE BEEN OBSERVED IN
LABORATORY RATS EXPOSED TO OVER 1000 PPM METHYL ETHYL KETONE FOR
MOST OF GESTATION PERIOD.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.